Continuous Flow Acoustofluidics in Wall-less Capillary Bridge Channels

Sadaf Maramizonouz, Jeremy J. Hawkes, Mohammad Rahmati*, Yongqing (Richard) Fu*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

24 Downloads (Pure)

Abstract

In this study, the manipulation, patterning, and alignment of yeast particles were successfully demonstrated inside a continuous flow capillary bridge channel. A numerical model is presented to explore various frequencies and channel configurations, and the numerical results are compared to the experimental findings. The numerical model produced results in excellent agreement with the experimental data. Yeast particles were aligned in linear patterns while continuously flowing parallel to the air-water interfaces of the capillary bridge channel. The width of the fluid-guide significantly affected the acoustic pressure fields and thus the quality of particle patterning. Most frequencies can achieve particle alignment inside the capillary bridge channel, while the liquid flow straightens the particle line. Studies of ultrasound transfer from a solid wave-guide into the liquid in a capillary bridge channel have previously shown that some nodes which formed in the waveguide will cross the solid-fluid interface into the water of the capillary bridge. The nodes formed by this extension mechanism are not easily distinguishable from nodes formed by a resonance in the liquid since particles are attracted to them in the same way and the node-to-node separation is often similar. This paper provides further foundation for the new node extension concept and identifies some of its unique features.
Original languageEnglish
Article number100275
Number of pages10
JournalSensors and Actuators Reports
Volume9
Early online date8 Jan 2025
DOIs
Publication statusE-pub ahead of print - 8 Jan 2025

Keywords

  • Acoustic manipulation
  • Acoustofluidics
  • Capillary bridge channel
  • Particle manipulation
  • Ultrasound
  • Yeast particle

Cite this