Skip to main navigation Skip to search Skip to main content

From failure to recovery: CFRP strengthening of a near-collapse reinforced concrete wastewater structure with root cause diagnosis, failure mechanisms, and structural implications under aggressive environmental conditions

Thushanthan Kannan*, Kumari Gamage, Chinthana Vimukthi

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Reinforced concrete structures in wastewater treatment plants (WWTPs) operate under uniquely aggressive conditions, including biogenic sulphuric acid attack, sustained moisture, elevated temperatures, and partial submergence. Although Fiber Reinforced Polymer (FRP) strengthening is well established for bridges and other concrete infrastructure, its application within WWTPs raises concerns regarding bond durability and long-term performance, and field case studies in such environments remain scarce. This paper presents the structural assessment and Carbon Fiber Reinforced Polymer (CFRP) rehabilitation of an industrial WWTP equalisation tank in Sri Lanka, in which a defective construction joint within an interior column had triggered progressive deterioration after 15 years of service, producing slab deflections of over 250 mm (span/32) far exceeding the BS 8110 serviceability limit of span/250. A multistage investigation combining visual crack survey, scanning electron microscopy (SEM-EDX), and three-dimensional finite element analysis identified two coexisting deterioration mechanisms: wastewater ingress through the defective joint, causing reinforcement corrosion and column fracture; and biogenic sulphuric acid attack within the tank headspace, producing ettringite formation in the slab and beam soffits. Rehabilitation was carried out under operational constraints, comprising column reconstruction, epoxy crack injection, externally bonded CFRP strengthening with elevated temperature post curing at 55–65°C to enhance the cured adhesive Tg, and protective finishing. An environmental reduction factor of 0.80, supported by accelerated ageing and lap shear bond data, was adopted in the strengthening design. Post rehabilitation analysis confirmed restoration of the vertical load path, reduction of peak bending moments, and re-establishment of structural continuity. The paper provides a complete diagnostic to rehabilitation workflow and practical guidance on material selection, surface preparation, post curing, and protective detailing for FRP applications in confined and chemically aggressive service environments.
Original languageEnglish
Pages (from-to)1-26
Number of pages26
JournalAdvances in Structural Engineering
Early online date26 Jun 2026
DOIs
Publication statusE-pub ahead of print - 26 Jun 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 6 - Clean Water and Sanitation
    SDG 6 Clean Water and Sanitation
  2. SDG 9 - Industry, Innovation, and Infrastructure
    SDG 9 Industry, Innovation, and Infrastructure

Keywords

  • CFRP retrofitting
  • Carbon Fiber Reinforced Polymer (CFRP)
  • acidic environment
  • construction joint failure
  • externally bonded reinforcement
  • finite element analysis
  • microbially induced concrete corrosion (MICC)
  • reinforced concrete durability
  • structural rehabilitation
  • wastewater treatment plant

Fingerprint

Dive into the research topics of 'From failure to recovery: CFRP strengthening of a near-collapse reinforced concrete wastewater structure with root cause diagnosis, failure mechanisms, and structural implications under aggressive environmental conditions'. Together they form a unique fingerprint.

Cite this