TY - JOUR
T1 - Improved mechanical performance and delayed corrosion phenomena in biodegradable Mg–Zn–Ca alloys through Pd-alloying
AU - Gonzalez Sanchez, Sergio
AU - Pellicer, Eva
AU - Fornell, Jordina
AU - Blanquer, Andreu
AU - Barrios, Lleonard
AU - Ibáñez, Elena
AU - Solsona, P.
AU - Suriñach, Santiago
AU - Baró, Maria
AU - Nogués, Carme
AU - Sort, Jordi
PY - 2012/2
Y1 - 2012/2
N2 - The influence of partial substitution of Mg by Pd on the microstructure, mechanical properties and corrosion behaviour of Mg72−xZn23Ca5Pdx (x=0, 2 and 6 at.%) alloys, synthesized by copper mould casting, is investigated. While the Mg72Zn23Ca5 alloy is mainly amorphous, the addition of Pd decreases the glass-forming ability, thus favouring the formation of crystalline phases. From a mechanical viewpoint, the hardness increases with the addition of Pd, from 2.71 GPa for x=0 to 3.9 GPa for x=6, mainly due to the formation of high-strength phases. In turn, the wear resistance is maximized for an intermediate Pd content (i.e., Mg70Zn23Ca5Pd2). Corrosion tests in a simulated body fluid (Hank’s solution) indicate that Pd causes a shift in the corrosion potential towards more positive values, thus delaying the biodegradability of this alloy. Moreover, since the cytotoxic studies with mouse preosteoblasts do not show dead cells after culturing for 27 h, these alloys are potential candidates to be used as biomaterials.
AB - The influence of partial substitution of Mg by Pd on the microstructure, mechanical properties and corrosion behaviour of Mg72−xZn23Ca5Pdx (x=0, 2 and 6 at.%) alloys, synthesized by copper mould casting, is investigated. While the Mg72Zn23Ca5 alloy is mainly amorphous, the addition of Pd decreases the glass-forming ability, thus favouring the formation of crystalline phases. From a mechanical viewpoint, the hardness increases with the addition of Pd, from 2.71 GPa for x=0 to 3.9 GPa for x=6, mainly due to the formation of high-strength phases. In turn, the wear resistance is maximized for an intermediate Pd content (i.e., Mg70Zn23Ca5Pd2). Corrosion tests in a simulated body fluid (Hank’s solution) indicate that Pd causes a shift in the corrosion potential towards more positive values, thus delaying the biodegradability of this alloy. Moreover, since the cytotoxic studies with mouse preosteoblasts do not show dead cells after culturing for 27 h, these alloys are potential candidates to be used as biomaterials.
KW - Nanoindentation
KW - Biomaterial
KW - Corrosion
KW - Elastic properties
U2 - 10.1016/j.jmbbm.2011.09.014
DO - 10.1016/j.jmbbm.2011.09.014
M3 - Article
SN - 1751-6161
VL - 6
SP - 53
EP - 62
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
ER -