TY - JOUR
T1 - Nonlinear Controller Design for Series-Compensated DFIG-Based Wind Farms to Mitigate Subsynchronous Control Interaction
AU - Chowdhury, Md Ayaz
AU - Mahmud, Md Apel
AU - Shen, Weixiang
AU - Pota, Hemanshu Roy
PY - 2017/6
Y1 - 2017/6
N2 - This paper proposes a nonlinear controller to mitigate subsynchronous control interaction (SSCI) in series-compensated doubly fed induction generator (DFIG)-based wind farms. The controller is designed based on partial feedback linearization (PFL) and the proposed design approach involves scrutinizing the partial feedback linearizability of the system. The stability of the internal dynamics, which is not transformed into linear autonomous subsystems by PFL, is also analyzed in the process of deriving the control laws. The frequency scanning method is used to evaluate the performance of the proposed PFL controller, and the performance is compared to that of a finely tuned conventional proportional integral controller. A grid-connected series-compensated 100-MW DFIG-based offshore wind farm is used to demonstrate the performance of the proposed scheme through the identification and mitigation of subsynchronous resonance. An analysis of the power system reveals that the resistance is negative across the entire subsynchronous frequency range, while the reactance becomes negative around 42 Hz. The proposed controller effectively mitigates SSCI, and it can be observed that it results in positive resistance and reactance values across the entire subsynchronous frequency range. Results from the eigenvalue (modal) analysis and electromagnetic transient simulation also confirm the results obtained from frequency scanning.
AB - This paper proposes a nonlinear controller to mitigate subsynchronous control interaction (SSCI) in series-compensated doubly fed induction generator (DFIG)-based wind farms. The controller is designed based on partial feedback linearization (PFL) and the proposed design approach involves scrutinizing the partial feedback linearizability of the system. The stability of the internal dynamics, which is not transformed into linear autonomous subsystems by PFL, is also analyzed in the process of deriving the control laws. The frequency scanning method is used to evaluate the performance of the proposed PFL controller, and the performance is compared to that of a finely tuned conventional proportional integral controller. A grid-connected series-compensated 100-MW DFIG-based offshore wind farm is used to demonstrate the performance of the proposed scheme through the identification and mitigation of subsynchronous resonance. An analysis of the power system reveals that the resistance is negative across the entire subsynchronous frequency range, while the reactance becomes negative around 42 Hz. The proposed controller effectively mitigates SSCI, and it can be observed that it results in positive resistance and reactance values across the entire subsynchronous frequency range. Results from the eigenvalue (modal) analysis and electromagnetic transient simulation also confirm the results obtained from frequency scanning.
KW - doubly-fed induction generator
KW - frequency scanning method
KW - internal dynamics
KW - partial feedback linearization
KW - Subsynchronous control interaction
UR - http://www.scopus.com/inward/record.url?scp=85028773941&partnerID=8YFLogxK
U2 - 10.1109/TEC.2017.2660539
DO - 10.1109/TEC.2017.2660539
M3 - Article
AN - SCOPUS:85028773941
SN - 0885-8969
VL - 32
SP - 707
EP - 719
JO - IEEE Transactions on Energy Conversion
JF - IEEE Transactions on Energy Conversion
IS - 2
M1 - 7835673
ER -