TY - JOUR
T1 - Novel Microfiber Sensor and Its Biosensing Application for Detection of hCG Based on a Singlemode-Tapered Hollow Core-Singlemode Fiber Structure
AU - Chen, Ling
AU - Liu, Bin
AU - Liu, Juan
AU - Wan, Sheng-Peng
AU - Wu, Tao
AU - Yuan, Jinhui
AU - Zhou, Xian
AU - Long, Keping
AU - Shao, Liyang
AU - Fu, Richard
AU - He, Xing-Dao
AU - Wu, Qiang
PY - 2020/8/15
Y1 - 2020/8/15
N2 - A novel microfiber sensor is proposed and demonstrated based on a singlemode-tapered hollow core-singlemode (STHS) fiber structure. Experimentally a STHS with taper waist diameter of 26.5μm has been fabricated and RI sensitivity of 816, 1601.86, and 4775.5 nm/RIU has been achieved with RI ranges from 1.3335 to 1.3395, from 1.369 to 1.378, and from 1.409 to 1.4175 respectively, which agrees very well with simulated RI sensitivity of 885, 1517, and 4540 nm/RIU at RI ranges from 1.3335 to 1.337, from 1.37 to 1.374, and from 1.41 to 1.414. The taper waist diameter has impact on both temperature and strain sensitivity of the sensor structure: (1) the smaller the waist diameter, the higher the temperature sensitivity, and experimentally 26.82 pm/°C has been achieved with a taper waist diameter of 21.4μm ; (2) as waist diameter decrease, strain sensitivity increase and 7.62 pm/ μ has been achieved with a taper waist diameter of 20.3μm. The developed sensor was then functionalized for human chorionic gonadotropin (hCG) detection as an example for biosensing application. Experimentally for hCG concentration of 5 mIU/ml, the sensor has 0.5 nm wavelength shift, equivalent to limit of detection (LOD) of 0.6 mIU/ml by defining 3 times of the wavelength variation (0.06 nm) as measurement limit. The biosensor demonstrated relatively good reproducibility and specificity, which has potential for real medical diagnostics and other applications.
AB - A novel microfiber sensor is proposed and demonstrated based on a singlemode-tapered hollow core-singlemode (STHS) fiber structure. Experimentally a STHS with taper waist diameter of 26.5μm has been fabricated and RI sensitivity of 816, 1601.86, and 4775.5 nm/RIU has been achieved with RI ranges from 1.3335 to 1.3395, from 1.369 to 1.378, and from 1.409 to 1.4175 respectively, which agrees very well with simulated RI sensitivity of 885, 1517, and 4540 nm/RIU at RI ranges from 1.3335 to 1.337, from 1.37 to 1.374, and from 1.41 to 1.414. The taper waist diameter has impact on both temperature and strain sensitivity of the sensor structure: (1) the smaller the waist diameter, the higher the temperature sensitivity, and experimentally 26.82 pm/°C has been achieved with a taper waist diameter of 21.4μm ; (2) as waist diameter decrease, strain sensitivity increase and 7.62 pm/ μ has been achieved with a taper waist diameter of 20.3μm. The developed sensor was then functionalized for human chorionic gonadotropin (hCG) detection as an example for biosensing application. Experimentally for hCG concentration of 5 mIU/ml, the sensor has 0.5 nm wavelength shift, equivalent to limit of detection (LOD) of 0.6 mIU/ml by defining 3 times of the wavelength variation (0.06 nm) as measurement limit. The biosensor demonstrated relatively good reproducibility and specificity, which has potential for real medical diagnostics and other applications.
KW - Hollow core fiber
KW - biosensor
KW - refractive index
KW - strain
KW - temperature
UR - http://www.scopus.com/inward/record.url?scp=85089223501&partnerID=8YFLogxK
U2 - 10.1109/jsen.2020.2986327
DO - 10.1109/jsen.2020.2986327
M3 - Article
SN - 1530-437X
VL - 20
SP - 9071
EP - 9078
JO - IEEE Sensors Journal
JF - IEEE Sensors Journal
IS - 16
M1 - 9062475
ER -