Abstract
Experimental techniques for determining the machine parameters and results demonstrating their performance on an axially-laminated synchronous reluctance motor are presented. A new software implementation of the control algorithm for conducting an instantaneous flux-linkage test is developed. A low frequency AC test allowing better estimation accuracy compared to a standard 50-Hz test is proposed. Effects of stator slotting on the quality of dc torque test estimates are examined.
Original language | English |
---|---|
Pages (from-to) | 264-269 |
Number of pages | 6 |
Journal | IEEE Transactions on Energy Conversion |
Volume | 14 |
Issue number | 3 |
DOIs | |
Publication status | Published - 1999 |
Externally published | Yes |