Abstract
Using coprime fractional techniques and H X -norms, the performance sensitivity of linear systems with five types of simultaneous structural uncertainty is analyzed. Sufficient conditions for the robust stability are derived. Also, the perturbed upper bounds for the sensitivity function matrix and the closed-loop transfer function matrix are presented
Original language | English |
---|---|
Pages (from-to) | 1537-1547 |
Journal | Systems Analysis Modelling Simulation |
Volume | 42 |
Issue number | 10 |
DOIs | |
Publication status | Published - 2002 |
Keywords
- coprime fractional techniques
- H ∞ -norm