TY - JOUR
T1 - Reproducibility of Anaerobic and Pain Thresholds in Male Patients With Intermittent Claudication
AU - da Rocha Chehuen, Marcel
AU - Cucato, Gabriel Grizzo
AU - Saes, Glauco Fernandes
AU - Costa, Luiz Augusto Riani
AU - Leicht, Anthony Scott
AU - Ritti-Dias, Raphael Mendes
AU - Wolosker, Nelson
AU - de Moraes Forjaz, Cláudia Lúcia
PY - 2016/9
Y1 - 2016/9
N2 - PURPOSE: Maximal and submaximal parameters assessed during treadmill tests are used to prescribe exercise training and assess exercise-induced adaptations in patients with intermittent claudication (IC). Although reproducibility of maximal parameters is well documented, the reproducibility of submaximal is not clear. The aim of this study was to identify the reproducibility (reliability and agreement) of heart rate (HR) and oxygen uptake ((Equation is included in full-text article.)O2) measured at the anaerobic (AT) and the pain (PT) thresholds assessed during a maximal test in patients with IC.METHODS: Twenty male patients with IC underwent 2 cardiopulmonary treadmill tests to maximal pain. The HR and (Equation is included in full-text article.)O2 at the AT and PT were identified, and differences between repeat tests were compared. Reliability was determined by intraclass coefficient correlation (ICC). Agreement was assessed by coefficient of variation (CV), standard error of measurement (SEM), smallest detectable difference (SDD), and limits of agreement (LOA).RESULTS: The (Equation is included in full-text article.)O2 at AT and PT exhibited moderate reliability and moderate/good agreement (ICC = 0.73 and 0.70; CV = 9.6% and 11.1%, respectively). The HR at the AT and PT exhibited high reliability and good agreement (ICC = 0.87 and 0.92; SEM = 3.9 and 3.2 bpm; SDD = 10.8 and 8.8 bpm, respectively). The LOA for (Equation is included in full-text article.)O2 at AT and PT were ≤20% and for HR ≤11 bpm.CONCLUSIONS: The (Equation is included in full-text article.)O2 and HR measured at the AT and PT were moderately to highly reproducible in male patients with IC. The HR and (Equation is included in full-text article.)O2 at AT and PT may be used to establish training intensity and evaluate training effectiveness for these patients in clinical practice and research.
AB - PURPOSE: Maximal and submaximal parameters assessed during treadmill tests are used to prescribe exercise training and assess exercise-induced adaptations in patients with intermittent claudication (IC). Although reproducibility of maximal parameters is well documented, the reproducibility of submaximal is not clear. The aim of this study was to identify the reproducibility (reliability and agreement) of heart rate (HR) and oxygen uptake ((Equation is included in full-text article.)O2) measured at the anaerobic (AT) and the pain (PT) thresholds assessed during a maximal test in patients with IC.METHODS: Twenty male patients with IC underwent 2 cardiopulmonary treadmill tests to maximal pain. The HR and (Equation is included in full-text article.)O2 at the AT and PT were identified, and differences between repeat tests were compared. Reliability was determined by intraclass coefficient correlation (ICC). Agreement was assessed by coefficient of variation (CV), standard error of measurement (SEM), smallest detectable difference (SDD), and limits of agreement (LOA).RESULTS: The (Equation is included in full-text article.)O2 at AT and PT exhibited moderate reliability and moderate/good agreement (ICC = 0.73 and 0.70; CV = 9.6% and 11.1%, respectively). The HR at the AT and PT exhibited high reliability and good agreement (ICC = 0.87 and 0.92; SEM = 3.9 and 3.2 bpm; SDD = 10.8 and 8.8 bpm, respectively). The LOA for (Equation is included in full-text article.)O2 at AT and PT were ≤20% and for HR ≤11 bpm.CONCLUSIONS: The (Equation is included in full-text article.)O2 and HR measured at the AT and PT were moderately to highly reproducible in male patients with IC. The HR and (Equation is included in full-text article.)O2 at AT and PT may be used to establish training intensity and evaluate training effectiveness for these patients in clinical practice and research.
KW - Aged
KW - Anaerobic Threshold
KW - Exercise Test
KW - Heart Rate
KW - Humans
KW - Intermittent Claudication/physiopathology
KW - Male
KW - Middle Aged
KW - Oxygen Consumption
KW - Pain Threshold
KW - Reproducibility of Results
U2 - 10.1097/HCR.0000000000000173
DO - 10.1097/HCR.0000000000000173
M3 - Article
C2 - 26959497
VL - 36
SP - 358
EP - 367
JO - Journal of Cardiopulmonary Rehabilitation and Prevention
JF - Journal of Cardiopulmonary Rehabilitation and Prevention
SN - 1932-7501
IS - 5
ER -