T1 - The wear of metal-on-metal total hip prostheses measured in a hip simulator.
AU - Scholes, S. C.
AU - Green, Sarah
AU - Unsworth, A.
PY - 2001/6/1
Y1 - 2001/6/1
N2 - New generation metal-on-metal prostheses have been introduced to try and overcome the problem of osteolysis often attributed to the wear particles of the polyethylene component of conventional metal-on-ultra-high molecular weight polyethylene (UHMWPE) joints. The wear rates of four metal-on-metal joints (two different clearances) were assessed along with that of a conventional metal-on-UHMWPE joint. Friction measurements of the metal-on-metal joints were taken before and after the wear test and compared. Two distinct wear phases were discernible for all the metal-on-metal joints: an initial wear phase up to 0.5 × 106 cycles and then a lower steady state wear phase. The steady state wear rate of the 22 μUm radial clearance metal-on-metal joint was lower than that for the 40 μUm radial clearance joint, although this difference was not found to be significant (p > 0.15). The wear rates for all the joints tested were consistent with other simulator studies. The friction factors produced by each joint were found to decrease significantly after wear testing (p < 0.05).
AB - New generation metal-on-metal prostheses have been introduced to try and overcome the problem of osteolysis often attributed to the wear particles of the polyethylene component of conventional metal-on-ultra-high molecular weight polyethylene (UHMWPE) joints. The wear rates of four metal-on-metal joints (two different clearances) were assessed along with that of a conventional metal-on-UHMWPE joint. Friction measurements of the metal-on-metal joints were taken before and after the wear test and compared. Two distinct wear phases were discernible for all the metal-on-metal joints: an initial wear phase up to 0.5 × 106 cycles and then a lower steady state wear phase. The steady state wear rate of the 22 μUm radial clearance metal-on-metal joint was lower than that for the 40 μUm radial clearance joint, although this difference was not found to be significant (p > 0.15). The wear rates for all the joints tested were consistent with other simulator studies. The friction factors produced by each joint were found to decrease significantly after wear testing (p < 0.05).
UR - https://puretest.lancaster.ac.uk/portal/en/publications/the-wear-of-metalonmetal-total-hip-prostheses-measured-in-a-hip-simulator(92616cb4-e3c8-4a1d-914d-df9122a5d1d6).html
U2 - 10.1243/0954411011536118
DO - 10.1243/0954411011536118
M3 - Article
SN - 0954-4119
JO - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
JF - Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
ER -