TY - JOUR
T1 - Ultrasensitive Detection of SCCA Employing a Graphene Oxide Integrated Microfiber Ring Laser Biosensor
AU - Li, Zefeng
AU - Xie, Ruen
AU - Sun, Guoyong
AU - Liu, Xiaokai
AU - Xin, Hu
AU - Chen, Yuping
AU - Chen, Shaobin
AU - Rao, Lan
AU - Yan, Binbin
AU - Wang, Kuiru
AU - Sang, Xinzhu
AU - Yu, Chongxiu
AU - Yuan, Jinhui
AU - Wu, Qiang
PY - 2024/9/10
Y1 - 2024/9/10
N2 - Squamous cell carcinoma antigen (SCCA) is one of the most commonly detected cancer biomarkers for a variety of cancers. In this paper, a microfiber ring laser biosensor with a graphene oxide linking layer for SCCA detection was proposed and experimentally demonstrated. SCCA antibody immobilized on graphene oxide surface binds specifically to SCCA, and induces refractive index variation over the surface of the microfiber biosensor, which leads to a wavelength shift of the microfiber ring laser biosensor. The experimental results show that the proposed laser biosensor can detect SCCA with concentrations from 0.01 to 50 ng/mL, and the calculated detection limit can be as low as 1.3 pg/mL. Additionally, the label-free quantitative detection of SCCA using the proposed microfiber biosensor was verified experimentally according to the corresponding regression equation, and the results agree well with clinical examination detection. This constructed microfiber biosensor may have promising practical applications in analytical detection, medical diagnostics, etc.
AB - Squamous cell carcinoma antigen (SCCA) is one of the most commonly detected cancer biomarkers for a variety of cancers. In this paper, a microfiber ring laser biosensor with a graphene oxide linking layer for SCCA detection was proposed and experimentally demonstrated. SCCA antibody immobilized on graphene oxide surface binds specifically to SCCA, and induces refractive index variation over the surface of the microfiber biosensor, which leads to a wavelength shift of the microfiber ring laser biosensor. The experimental results show that the proposed laser biosensor can detect SCCA with concentrations from 0.01 to 50 ng/mL, and the calculated detection limit can be as low as 1.3 pg/mL. Additionally, the label-free quantitative detection of SCCA using the proposed microfiber biosensor was verified experimentally according to the corresponding regression equation, and the results agree well with clinical examination detection. This constructed microfiber biosensor may have promising practical applications in analytical detection, medical diagnostics, etc.
KW - Fiber ring laser biosensor
KW - Graphene oxide
KW - Microfiber biosensor
KW - SCCA detection
UR - http://www.scopus.com/inward/record.url?scp=85203657242&partnerID=8YFLogxK
U2 - 10.1016/j.bios.2024.116772
DO - 10.1016/j.bios.2024.116772
M3 - Article
SN - 0956-5663
VL - 267
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
M1 - 116772
ER -