TY - JOUR
T1 - Validity of six activity monitors in chronic obstructive pulmonary disease
T2 - A comparison with indirect calorimetry
AU - The PROactive Consortium
AU - van Remoortel, Hans
AU - Raste, Yogini
AU - Louvaris, Zafeiris
AU - Giavedoni, Santiago
AU - Burtin, Chris
AU - Langer, Daniel
AU - Wilson, Frederick
AU - Rabinovich, Roberto
AU - Vogiatzis, Ioannis
AU - Hopkinson, Nicholas S.
AU - Troosters, Thierry
PY - 2012/6/20
Y1 - 2012/6/20
N2 - Reduced physical activity is an important feature of Chronic Obstructive Pulmonary Disease (COPD). Various activity monitors are available but their validity is poorly established. The aim was to evaluate the validity of six monitors in patients with COPD. We hypothesized triaxial monitors to be more valid compared to uniaxial monitors. Thirty-nine patients (age 68±7years, FEV1 54±18%predicted) performed a one-hour standardized activity protocol. Patients wore 6 monitors (Kenz Lifecorder (Kenz), Actiwatch, RT3, Actigraph GT3X (Actigraph), Dynaport MiniMod (MiniMod), and SenseWear Armband (SenseWear)) as well as a portable metabolic system (Oxycon Mobile). Validity was evaluated by correlation analysis between indirect calorimetry (VO2) and the monitor outputs: Metabolic Equivalent of Task [METs] (SenseWear, MiniMod), activity counts (Actiwatch), vector magnitude units (Actigraph, RT3) and arbitrary units (Kenz) over the whole protocol and slow versus fast walking. Minute-by-minute correlations were highest for the MiniMod (r = 0.82), Actigraph (r = 0.79), SenseWear (r = 0.73) and RT3 (r = 0.73). Over the whole protocol, the mean correlations were best for the SenseWear (r = 0.76), Kenz (r = 0.52), Actigraph (r = 0.49) and MiniMod (r = 0.45). The MiniMod (r = 0.94) and Actigraph (r = 0.88) performed better in detecting different walking speeds. The Dynaport MiniMod, Actigraph GT3X and SenseWear Armband (all triaxial monitors) are the most valid monitors during standardized physical activities. The Dynaport MiniMod and Actigraph GT3X discriminate best between different walking speeds.
AB - Reduced physical activity is an important feature of Chronic Obstructive Pulmonary Disease (COPD). Various activity monitors are available but their validity is poorly established. The aim was to evaluate the validity of six monitors in patients with COPD. We hypothesized triaxial monitors to be more valid compared to uniaxial monitors. Thirty-nine patients (age 68±7years, FEV1 54±18%predicted) performed a one-hour standardized activity protocol. Patients wore 6 monitors (Kenz Lifecorder (Kenz), Actiwatch, RT3, Actigraph GT3X (Actigraph), Dynaport MiniMod (MiniMod), and SenseWear Armband (SenseWear)) as well as a portable metabolic system (Oxycon Mobile). Validity was evaluated by correlation analysis between indirect calorimetry (VO2) and the monitor outputs: Metabolic Equivalent of Task [METs] (SenseWear, MiniMod), activity counts (Actiwatch), vector magnitude units (Actigraph, RT3) and arbitrary units (Kenz) over the whole protocol and slow versus fast walking. Minute-by-minute correlations were highest for the MiniMod (r = 0.82), Actigraph (r = 0.79), SenseWear (r = 0.73) and RT3 (r = 0.73). Over the whole protocol, the mean correlations were best for the SenseWear (r = 0.76), Kenz (r = 0.52), Actigraph (r = 0.49) and MiniMod (r = 0.45). The MiniMod (r = 0.94) and Actigraph (r = 0.88) performed better in detecting different walking speeds. The Dynaport MiniMod, Actigraph GT3X and SenseWear Armband (all triaxial monitors) are the most valid monitors during standardized physical activities. The Dynaport MiniMod and Actigraph GT3X discriminate best between different walking speeds.
UR - http://www.scopus.com/inward/record.url?scp=84862654624&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0039198
DO - 10.1371/journal.pone.0039198
M3 - Article
C2 - 22745715
AN - SCOPUS:84862654624
SN - 1932-6203
VL - 7
JO - PLoS One
JF - PLoS One
IS - 6
M1 - e39198
ER -