Abstract
The UK construction industry faces two significant challenges: addressing the housing shortage while reducing the environmental impact associated with construction activities. Achieving national housing targets while limiting carbon emissions requires the adoption of sustainable materials, improved structural design approaches, and wider use of modern methods of construction such as modular construction and prefabrication. Cold-formed Steel (CFS) members are increasingly used in these systems due to their high strength-to-weight ratio, efficient use of material, and suitability for off-site manufacturing.Despite these advantages, the thin-walled nature of CFS sections makes them susceptible to complex buckling failure, including local, distortional, and lateral torsional buckling. To improve structural performance and material efficiency, alternative cross-sections have been proposed. This thesis investigates the structural behaviour of three CFS sections, including two longitudinally web stiffened members the Double-Sigma, Sigma and one hollow section, the MCO beam.
Finite element (FE) models were developed using the commercially available software ABAQUS. The numerical models were validated against experimental results from literature to ensure reliable prediction of structural behaviour. Comparisons of ultimate section moment capacity, shear capacity, load–displacement response, and failure modes indicated that the FE models provide accurate predictions of both flexural and shear behaviour.
The flexural behaviour of Sigma and Double-Sigma sections was investigated using four-point bending set-up to promote predominate bending failure. A parametric study of 100 FE models for the Double-Sigma and 120 FE models FE Sigma models were conducted to examine the influence of key parameters including section thickness, yield strength, cross-sectional geometry, and longitudinal web stiffener angle. For both sections, local buckling was observed to govern failure. Among the parameters considered, section thickness had the greatest influence on flexural capacity. It was also observed that increasing the longitudinal web stiffener angle from 10° to 60° resulted in a reduction in flexural capacity. Modified design equations to capture the inelastic behaviour of the Double-Sigma section are proposed, where as existing design standards for the Sigma section were found to be sufficient.
Following the flexural investigation, the shear behaviour of Sigma sections incorporating longitudinal web stiffeners to plain web channel sections was examined. A FE parametric study consisting of 120 models was conducted to evaluate the influence of geometric and material parameters on the ultimate shear capacity of the section. The results indicated that existing design provisions based on the Direct Strength Method (DSM) tend to produce conservative predictions for the investigated configurations. Similar to the flexural behaviour, section thickness was found to have the greatest influence on ultimate shear capacity, while increasing the web stiffener angle reduced the shear resistance of the section.
The shear performance of the MCO beam, was also investigated. A numerical parametric study consisting of 105 models was conducted to examine the influence of key parameters on ultimate shear capacity. The results suggested that existing design rules provide conservative predictions for this section, with the MCO beam experiencing significant inelastic reserve for compact sections. Based on the parametric study, modified design expressions within the DSM guidelines were proposed. Among the investigated parameters, thickness was identified as the most influential factor affecting shear capacity.
In addition to the numerical investigation, machine learning techniques were explored as an alternative method for predicting the shear capacity of the MCO beam. Six machine learning models were evaluated using the dataset generated from the FE parametric study. Among these models, the Artificial Neural Network (ANN) provided the most accurate predictions. Explainable machine learning techniques were applied to examine the relative importance of the input parameters, indicating that thickness and yield strength had the greatest influence on the predicted ultimate shear capacity.
Overall, the results indicate that current design rules for bending and shear in CFS members are conservative for the investigated sections. The findings of this research therefore contribute to improved understanding of the structural behaviour of web stiffened sections and hollow-flange beams and provide modified design equations that may improve the accuracy of capacity predictions within the DSM. However, this thesis is primarily based on validated numerical simulations, with experimental data taken from previously published studies. The investigation focuses on the generalised structural behaviour rather than individual experimental responses In addition, the parametric studies consider a defined range of geometric and material properties representative of standard CFS applications.
Within these limitations, the results are applicable to the design and analysis of CFS members used in lightweight structural systems, including floor joists and modular construction applications. The proposed design expressions assist in improving the efficiency of structural design by reducing unnecessary conservatism in capacity predictions, thereby supporting more efficient use of materials and reduced embodied carbon in construction. Although due to validation from existing literature, future work is required for experimental validation of the individual sections considered in this thesis.
| Date of Award | 28 May 2026 |
|---|---|
| Original language | English |
| Awarding Institution |
|
| Supervisor | Keerthan Poologanathan (Supervisor), Marco Corradi (Supervisor), Hoang Nguyen (Supervisor), Mohammadali Rezazadeh (Supervisor) & Vikki Edmondson (Supervisor) |
Keywords
- Structural Engineering
- Civil Engineering
- Modular Construction
- Carbon Steel
- Bending and shear resistance
Cite this
- Standard